What failures will occur in the air compressor inverter

Time: 2023-01-18 Views: 709 times

Air compressor inverter is a special type of inverter tailored for all kinds of air compressors, air compressor inverter and other mechanical equipment, the use of a long time will also fail, then the air compressor inverter will appear what failures?

1.Voltage instability

Under normal circumstances, the frequency conversion air compressor will be used for a long time, there will be voltage instability, once the voltage is unstable, there will be load phenomenon, at this time our cylinder pressure will also change, at this time we need to adjust the regulator。
2.Main board damage
The use of variable frequency air compressor for a long time is easy to cause damage to the motherboard, once the motherboard is damaged, our internal components can not carry out normal work to release the air pressure, so we need to regularly check and replace the motherboard of the air compressor inverter。
3.Heat dissipation fan is damaged
另外,Our air compressor inverter is also prone to failure in long-term hot weather,Especially in the summer, we need to regularly check the heat dissipation channel of the air compressor inverter,Check whether congestion exists,Or we can pay attention to whether the cooling fan is damaged and deal with it through replacement or maintenance in time。
4.Lack of displacement
There is a sudden lack of exhaust volume in the process of operation of the time-space press equipment,At this time, you can view the intake filter of the variable frequency air compressor,See if there is dirt accumulation causing obstruction and reducing the exhaust volume,Or the suction tube is too long and the tube cross-section is too small, resulting in gas reduction can not pass smoothly,It only needs to be cleaned or replaced frequently。
5.External input fault
There will also be external input failures during the operation of the variable frequency air compressor, and external failures will also cause the entire variable frequency air compressor to not work normally。External failure Generally can detect whether the voltage value of the port is normal, and check whether the short-circuit cap connected to the control panel and the device is dropped, and can also use the wire short-circuit emergency stop switch to see whether it is damaged, and the external input fault can be handled by replacing or installing。